- Change the sample time of the Simulink signal where io(1) is located to a continuous sample time
- Use frest.createFixedTsSinestream to create a sinestream signal that has a single sample rate
when i run frestimate(mdl,io,in) , it comes out following warnings, what can i do~
    10 vues (au cours des 30 derniers jours)
  
       Afficher commentaires plus anciens
    
??? Error using ==> frestimate>LocalCheckDataTypeAndSampleTime at 532
In "frestimate(modelname,op,io,in)", the input signal "in" is a
frest.Sinestream signal which has parameter values for "Frequency" and
"SamplesPerPeriod" such that it inherently has multiple sample times.
Using such an input signal requires that samples rates belonging to the
Simulink signals where your linearization input and output points are
located are either continuous or fixed in minor time step and the
linearization I/O io(1) does not satisfy this requirement. Consider either
changing the sample time of Simulink signal where io(1) is located to
continuous sample time or using frest.createFixedTsSinestream utility to
create a sinestream signal that has a single sample rate.
Error in ==> frestimate>LocalSetupForSimulation at 379
isVarTs = LocalCheckDataTypeAndSampleTime(table,in,ModelParameterMgr);
Error in ==> frestimate at 94
[parammgr,SimulationPackage] =
LocalSetupForSimulation(model,io,op,in,numout,opts);
0 commentaires
Réponses (2)
  Arnaud Miege
      
 le 26 Avr 2011
        The error message suggests two things, have you tried them?
Without seeing the model and the code, it's difficult to be more specific.
HTH,
Arnaud
5 commentaires
  Arnaud Miege
      
 le 28 Avr 2011
				Can you explain about the I/O points? Do you mean the inputs and outputs of the PID controller? Why openloop? What are you trying to get the frequency response of? Shouldn't the I/O points be at the top-level of the model, e.g. w* and w? Also, are you aware that you are using a discrete sample time of 1s for your PID controller, whereas your electrical model has been discretized with a sample time of 1e-5s? Is that really what you intend to do?
  SimTec
 le 26 Fév 2018
        Dear Miege, How can we Change the sample time of the Simulink signal where io(1) is located to a continuous sample time, I right-click on the io and I could not see any parameter related to sample time best regards
2 commentaires
  Abdullah Al Masud
 le 17 Juin 2019
				Hello Zhao,
I am also having the same problem. Have you found any solution yet?
  MULTAN007
 le 7 Mai 2020
				Hi,
James Zhao, TarikTech and Abdullah Al Masud, did you get the solution for this issue? I'm having same sitation. Thanks in advance for your response and time. 