Can not convert USHORT MAX to ufix16_Sp01

2 vues (au cours des 30 derniers jours)
galaxy
galaxy le 19 Nov 2020
Commenté : galaxy le 19 Nov 2020
Dear bros,
In Simulink model, I use constant block which has value (65535) and data type is ufix16_Sp01 (fixdt(0,16,0.01,0)). But there is error
I understand that ufix16_Sp01 is unsigned with wordlength is 16.
So, Can anyone explain for me???

Réponse acceptée

James Tursa
James Tursa le 19 Nov 2020
If you have a slope scaling of 0.01 and a bias of 0, doesn't that mean the max value is 65535*0.01 = 655.35?
  1 commentaire
galaxy
galaxy le 19 Nov 2020
I am wrong.
Thank you so much

Connectez-vous pour commenter.