"Virtual bus without a bus object is not supported by the Test Sequence block" error message using bus object

26 vues (au cours des 30 derniers jours)
I am encountering an issue when trying to use a bus object I created with "Simulink.Bus.createObject". The bus signal goes into a subsystem that I want to create a Test Harness for, which accepts a "Test Sequence" as an input.
I got the following error message:
The input 1 of the component has virtual bus without a bus object. Virtual bus without a bus object is not supported by the Test Sequence block.
Please refer to the following screenshot below.

Réponse acceptée

MathWorks Support Team
MathWorks Support Team le 1 Sep 2020
The issue is resolved by specifying the "Output data type" field of the "Bus Creator" block to be the created bus object (originally set as Inherit auto). A simple reproduction model is attached for convenience.