"Virtual bus without a bus object is not supported by the Test Sequence block" error message using bus object
26 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
MathWorks Support Team
le 1 Sep 2020
Réponse apportée : MathWorks Support Team
le 7 Déc 2020
I am encountering an issue when trying to use a bus object I created with "Simulink.Bus.createObject". The bus signal goes into a subsystem that I want to create a Test Harness for, which accepts a "Test Sequence" as an input.
I got the following error message:
The input 1 of the component has virtual bus without a bus object. Virtual bus without a bus object is not supported by the Test Sequence block.
Please refer to the following screenshot below.

Réponse acceptée
MathWorks Support Team
le 1 Sep 2020
The issue is resolved by specifying the "Output data type" field of the "Bus Creator" block to be the created bus object (originally set as Inherit auto). A simple reproduction model is attached for convenience.