Simulink Problem: Derivative input is Inf

14 vues (au cours des 30 derniers jours)
Fan
Fan le 9 Mai 2013
Hi,
I face a Simulink problem at the input of the integration block, which is:
Derivative input 1 of 'diode4_1_test/Integrator' at time 0.00050002112037682831 is Inf or NaN. Stopping simulation. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances)
However,the input of the integration block is not infinity according the scope. I also tried to put saturation block at the input, but the problem also exists.
Thank you!
  1 commentaire
Jordan Monthei
Jordan Monthei le 9 Mai 2013
It would be helpful to see what sort of system you are trying to run as well as what is seen on the scope to have a better understanding of your problem.

Connectez-vous pour commenter.

Réponse acceptée

Guy Rouleau
Guy Rouleau le 9 Mai 2013
Use the Simulink debugger to identify where the Inf or NaN originates. There is a "NaN" breakpoint.

Plus de réponses (1)

Brahim MOUDOUD
Brahim MOUDOUD le 7 Oct 2019
Hi,
I had the same problem for the integrator
Derivative of state '1' in block '..../integrator' at time 4.4501477170144018E-309 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances)
Thank you .

Catégories

En savoir plus sur Simulink Functions dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by