Effacer les filtres
Effacer les filtres

Not getting desired waveform when using the hdl supported free running counter

3 vues (au cours des 30 derniers jours)
I have generated a sine pwm using sine-triangle comparison method. The sawtooth waveform is generated by a free running (HDL supported)counter with 6-bit. The stepped waveform generated contains only six or seven steps, this I believe incorrect. For a six bit counter, I expect a stepped sawtooth waveform with 64 steps, but I am getting only 6 to 7 stepped sawtooth waveform (Amplitude > 60)!!
Any idea what problem it is?
The solver used is fixed and discrete. This is selected because I want to convert the model into HDL code (Verilog code).
Any further details required..
Regards,

Réponse acceptée

Tim McBrayer
Tim McBrayer le 31 Mai 2013
Modifié(e) : Tim McBrayer le 31 Mai 2013
The HDL Counter has (among other mask parameters) initial value, step value, and count to value. I think you are confusing the count to value with counter bit width. if you want a 64-value counter, one way to configure it is with a start value of 0, a stop value of 63, and an increment of 1. The numeric type for the counter's output is an entirely separate set of configurable mask parameters.

Plus de réponses (0)

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!