i designed my own filter coefficeints and got the result .. want to know whether my results are better or not than db4

1 vue (au cours des 30 derniers jours)
my results are
The compression ratio is 28.0859
Retained Energy is 100.0000
PSNR value of decompressed image is 87.8646
and for 'db4' filter coefficients i got the result as
The compression ratio is 44.4661
Retained Energy is 99.9996
PSNR value of decompressed image is 113.4202

Réponse acceptée

Jan
Jan le 5 Juin 2013
How do you want to measure "better"?
Obviously your function performs a stronger compression for the costs of a lower PSNR, while the reatined energy is almost equal.
If the memory is limited, your method is "better". When quality is more important db4 is "better".