Problem with TCP/IP Send Block in Simulink

26 vues (au cours des 30 derniers jours)
Stephanie
Stephanie le 25 Juil 2013
Commenté : Rik le 17 Mai 2021
I am sending hardcoded values to a remote instrument via TCP/IP in Simulink. However, I keep getting the error: 'Error evaluating registered method 'Start' of MATLAB S-Function 'stcpipsb' in 'TestSend2/TCP//IP Send'.' What could be causing this? What configuration parameters might I need to change?

Réponses (1)

Jitesh Patel
Jitesh Patel le 27 Juil 2018
In case anyone else is looking for answer - the TCP/IP blocks requires a server to be running with exact port available.
So running the command "echotcpip('on',50000)" before running simulation will get rid of the error when you are working on one computer and you don't have the actual server available. Note: 1) either the command can be added in some simulink model callback (preload/init) 2) change the port number to match with your need
Hope it helps...
  1 commentaire
Rik
Rik le 17 Mai 2021
Comment posted as flag by Edward P Frye:
That works! Thanks.