how to solve the integer multiple of fixed-step size

230 vues (au cours des 30 derniers jours)
Ryan loh
Ryan loh le 19 Mai 2021
Commenté : Nur Aida Ariffah le 25 Août 2023
when play the drive train
Invalid setting for fixed-step size (10000000.0) in model 'Drivetrain'. All sample times in your model must be an integer multiple of the fixed-step size.
Component:Simulink | Category:Model error
The sample time period (5.0E-5) of 'Drivetrain/Drivetrain/Discrete-Time Integrator ' is not an integer multiple of the fixed step size (10000000.0) specified for model.
Component:Simulink | Category:Model error
The sample time period (5.0E-5) of 'Drivetrain/Drivetrain/Discrete-Time Integrator1' is not an integer multiple of the fixed step size (10000000.0) specified for model.

Réponses (1)

Aghamarsh Varanasi
Aghamarsh Varanasi le 25 Mai 2021
Hi,
The Fixed-step size is the time interval after which the solver solves a Simulink model. Hence, all the sample times in a Simulink model must be an integer multiple of the fixed-step size. In your example, the fixed-step size is 10000000(e7). And the sample time for the block 'Drivetrain/Drivetrain/Discrete-Time Integrator' is '5e-5', which is not an integer multiple of e7.
To solve this issue, you can set the fixed-step size of the model to be 'auto'. You can find this settings in the Solver > Solver Details > Fixed-Step Size in the Model settings.
Hope this helps
  1 commentaire
Nur Aida Ariffah
Nur Aida Ariffah le 25 Août 2023
Hi, I have the same problem and i tried this method but it didn't work

Connectez-vous pour commenter.

Catégories

En savoir plus sur Modeling dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by