Change the minimum displacement of a variable-displacement pressured-compensated pump
6 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Sebastian Stumpf
le 11 Juin 2021
Commenté : Jocie Kluger
le 21 Juin 2021
Hello,
I am using a variable-displacement pressured-compensated pump in my hydraulic system. The MathWorks Help says: The displacement can be changed from its maximum value down to zero. Is there a way to change the minimum displacement from zero to another value smaller than its maximum displacement? For expample: The datasheet provides a p-Q-Diagram of a variable-displacement pressured-compensated pump with a maximium displacement of 35 L/min at minimum pressure and a minimum displacement of 5 L/min at maximum pressure.
Thank you very much for your help
Best regards,
Sebastian
0 commentaires
Réponse acceptée
Jocie Kluger
le 11 Juin 2021
Hi Sebastian,
This is a limitation of the Variable-Displacement Pressure-Compensated Pump in the Hydrualic domain. The Pressure-Compensated Pump (IL) in the Isothermal Liquid library has an option to set a nonzero Minimum displacement. You can interface the Isothermal Liquid block with the Hydraulic domain network using an Interface (H-IL) block, or upgrade the entire model to the new Isothermal Liquid domain using the hydraulicToIsothermalLiquid function.
Regards,
Jocie
6 commentaires
Jocie Kluger
le 21 Juin 2021
I'm glad to hear you resolved the issue and the results match real-world data. It's a neat workaround trick.
Regards,
Jocie
Plus de réponses (0)
Voir également
Catégories
En savoir plus sur Upgrading Hydraulic Models to Use Isothermal Liquid Blocks dans Help Center et File Exchange
Produits
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!