Interpretation of Simulink block warning
10 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hello,
I'm back to Simulink after a few years of absence. However, I ran into following warning during simulation, which I've never seen before. And which I still can't interprete after reading it 5 times:
Minimum '-400' and maximum '400' from 'FOC_Controller/PI Controller/U_d' are mapped to a portion of the wide signal coming from 'Output Port 1' of 'FOC_Controller/PI Controller/DQ Limiter/Switch' and have been ignored during range checking. To enable the range checking for the minimum and maximum values, insert a Signal Conversion block with its 'Output' parameter set to 'Signal copy' in front of 'FOC_Controller/PI Controller/U_d'.
Only the bold sentence is unclear to me.
Thanks in advance and greetings,
Thomas
0 commentaires
Réponses (2)
Jonas
le 8 Juil 2021
You have defined minimum and maximum values of a certain output or signal, and then probably created a vector of it using a Mux block. The diagnostics complains that that min/max range is only defined for part of the vector signal.
That's my guess, because it's otherwise difficult to assess without seeing your model.
0 commentaires
Voir également
Catégories
En savoir plus sur Sources dans Help Center et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!