Normalization of a given filter to have unity gain at DC
13 vues (au cours des 30 derniers jours)
Afficher commentaires plus anciens
Hello everyone,
As the title says, I should find a general way to normalize some filters to have unity gain at DC. My filters are an Hanning window (note that b/d and a/c are the vectors in which are reported the coefficients of, respectively, numerator and denominator of the transfer function of the filters)
b = [0.25 0.5 0.25];
a = [1 0 0];
And a derivative-based filter:
d = [1 -1];
c = [1 -0.95]
Any help will be greatly appreciated.
0 commentaires
Réponse acceptée
Honglei Chen
le 8 Oct 2013
I don't quite understand your question. For example, in your filter formed by d and c, it has a null at DC, how do you expect it to have a unit gain at DC?
In general, if you have filter coefficients b and a, the DC gain is given by sum(b)/sum(a). You can just scale the filter response accordingly.