Heat Exchanger Solver

Version 1.0.0.0 (2,37 ko) par Seyyed Ali
Calculating outlet temperatures of a Heat Exchanger using Epsilon-NTU method
4,3K téléchargements
Mise à jour 21 avr. 2014

Afficher la licence

The main function is HeatExchanger.m that calculates the outlet temperatures of a heat exchanger using Epsilon-NTU (E-NTU) method. This function uses effectiveness.m as a function and should have access to it.
The inputs are as follows:
Hot Flow: c_p_hot, m_dot_hot, T_hot_in.
Cold Flow: c_p_cold, m_dot_cold, T_cold_in.
Heat exchanger design parameters: U,A, HE_Type.
HE_Type defines the type of heat exchanger: (see reference)
  'Parallel Flow'
  'Counter Flow'
  'One Shell Pass'
  'N Shell Pass'
  'Cross Both Unmixed'
  'Cross Cmax Mixed'
  'Cross Cmin Mixed'
The second function is effectiveness.m which calculates the effectiveness of a heat exchanger : epsilon = f(NTU,C_r)
See Reference for definitions.
Third file is a test script that shows an example of using this function.
Reference:
Frank P. Incropera, Introduction to heat transfer. New York:Wiley, 1985, Section 11.4.

Citation pour cette source

Seyyed Ali (2024). Heat Exchanger Solver (https://www.mathworks.com/matlabcentral/fileexchange/46303-heat-exchanger-solver), MATLAB Central File Exchange. Récupéré le .

Compatibilité avec les versions de MATLAB
Créé avec R2013a
Compatible avec toutes les versions
Plateformes compatibles
Windows macOS Linux
Remerciements

A inspiré : Heat exchanger

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!
Version Publié le Notes de version
1.0.0.0