Enabled Subsystem does not reliably disable
Not sure if you still need an answer to this, but the sample time colors give you a hint at what's causing the weird behavior: ...
3 mois il y a | 0
| A accepté
AST --> CGScope Error When Using Custom Code
You're hitting a bug with the parser that Simulink uses to parse through all symbols in your header file. If you are able to sha...
10 mois il y a | 0
C Caller with Multidimensional Signals in Simulink
You need to specify the dimension is "3" on the C Caller block:
12 mois il y a | 0
Simulink C-caller with persistent fcn
You could use the C Function block instead. The C Function block lets you put that code directly in the block mask, and it also ...
12 mois il y a | 0
Problem with C-Caller
Your model runs and produces results on my end. It's possible that the scope is not scaled properly for you to see the output. T...
environ 2 ans il y a | 0
Non-static tunable parameters in C++ class code generation.
Generating non-static parameters is supported starting in R2021a. See this post for instructions on how to configure the model: ...
plus de 2 ans il y a | 0
How can I debug a simulink C caller block in Visual Studio?
In R2022a, a new feature was introduced to make it easy to debug custom code. You can refer to this page: https://www.mathworks....
plus de 3 ans il y a | 0
Signal Logging in a Protected Reference Model
Hi Vincenzo, You are correct that you cannot log signals inside a Protected Model. As a workaround, you have 3 options: 1) Bri...
presque 5 ans il y a | 0
Using Discrete PID Significantly Slows Down Simulation
This is most likely happening because you have a discrete controller driving a continuous variable-step plant. As mentioned in t...
plus de 5 ans il y a | 1