Question
How can I load a final state of a Simscape model in generated code?
Hi! I have a Simscape model of which I generate code for deployment. This works great if I start the simulation at defined simp...
4 mois il y a | 2 réponses | 0
2
réponsesQuestion
Solver resets due to discrete signal at ps-simulink-converter
Hi! Using the Solver Profiler with a fixed-step model (ode3) I get a lot of solver resets due to discrete signal at a "ps-simul...
plus de 2 ans il y a | 1 réponse | 0
1
réponseQuestion
Index problems after version upgrade
Hi! I have a Simscape model running with R2020a. Now I upgraded to R2021a. Without any changes I get the following error when ...
plus de 4 ans il y a | 1 réponse | 0
0
réponseQuestion
The only high priority target the model has ist not met
Hello, I have a translational model that has only one variable which shall have a specified initial condition (start position)....
presque 5 ans il y a | 1 réponse | 0
0
réponseWhich settings make Input/Output structs of generated code public again?
I found a way which is not really satisfying, but which leads to the solution I wanted: The way to go was to use the Quickstart...
plus de 5 ans il y a | 0
| A accepté
Question
Which settings make Input/Output structs of generated code public again?
Hi! I used the simulink coder to generate c++ code of a simscape models. The resulting MyModel.h contains a class called <MyMod...
plus de 5 ans il y a | 1 réponse | 0
1
réponseQuestion
Mux/Demux for physical signals
Hi! Given a physical signal vector, how can I split up the vector into its components? That would be something like Mux/Demux f...
plus de 5 ans il y a | 1 réponse | 0
1
réponseLogging with referenced model
For others who might come across this question I'd like to provide the workaround that comes closest to a solution for me. Inste...
plus de 5 ans il y a | 0
| A accepté
Question
Simscape ignores parameter units
Hi! I have a problem with a custom component. For investigation purposes I created the followinf minimal example of what I try ...
environ 6 ans il y a | 1 réponse | 0
0
réponseQuestion
Logging with referenced model
Hello, I have a simscape model that I want to run via sim() command for testing purposes. Since I have input data that depends ...
environ 6 ans il y a | 2 réponses | 0