Statistiques
RANG
14 324
of 295 467
RÉPUTATION
3
CONTRIBUTIONS
8 Questions
2 Réponses
ACCEPTATION DE VOS RÉPONSES
62.5%
VOTES REÇUS
2
RANG
of 20 234
RÉPUTATION
N/A
CLASSEMENT MOYEN
0.00
CONTRIBUTIONS
0 Fichier
TÉLÉCHARGEMENTS
0
ALL TIME TÉLÉCHARGEMENTS
0
CONTRIBUTIONS
0 Publications
CONTRIBUTIONS
0 Public Chaîne
CLASSEMENT MOYEN
CONTRIBUTIONS
0 Point fort
NOMBRE MOYEN DE LIKES
Feeds
How to connect a Simscape Fluids/Centrifugal Pump to Specialized Technology/Asynchronous Machine
Hello, You can do this by changing the Asynchronous Machine to have its Mechanical Input set to *Mechanical rotational port* ...
environ 8 ans il y a | 1
| A accepté
Question
B:\ Permission Issue
Hello, Whenever I try to change to B:\ on my machine I get: |Error using cd| |Cannot CD to b:\ (Directory permission de...
plus de 8 ans il y a | 1 réponse | 0
0
réponseQuestion
How to connect a Simscape Fluids/Centrifugal Pump to Specialized Technology/Asynchronous Machine
Hello, I would like to connect a Specialized Technology/Asynchronous Machine to Fluids/Hydraulics/Centrifugal Pump. How d...
plus de 8 ans il y a | 1 réponse | 0
1
réponseQuestion
Harmonic Generation in Simulink
Hello, I would like to generate up to the 200th harmonic of a fundamental frequency with adjustable magnitude for each harmo...
presque 9 ans il y a | 1 réponse | 0
1
réponseQuestion
How to create Dynamic Plot Labels
Hello, I have 18 data sets against time to plot. I would like to have text which describes what each one is at the end of the...
environ 9 ans il y a | 1 réponse | 0
0
réponseQuestion
GUI Development - Missing border around Push Button
Hello, I am making a GUI and when I preview the GUI push buttons in GUIDE it looks okay. However when I use the deploytool an...
environ 9 ans il y a | 1 réponse | 1
1
réponseQuestion
Simpowersystems Asynchronous Machine Inside Delta (6 wire) connection
Hello, Is there a way to access all six stator winding connection points using this model to allow inside delta (6 wire) con...
plus de 9 ans il y a | 1 réponse | 0
1
réponseQuestion
Simulink SimPowerSystems Breaker - Tunable on resistance, Ron
Hello, I am using a simpowersystems breaker block in Simulink and loading the simulation model I created onto a Real-Time ta...
plus de 9 ans il y a | 1 réponse | 0
1
réponseThree-Phase Fault Parameter Values of Simulink Model in Real-Time Target
Hi everyone, I worked out how to do this. I created a block where I used the SimPowerSystems parts *Variable Resistor, Solver...
environ 10 ans il y a | 0
| A accepté
Question
Three-Phase Fault Parameter Values of Simulink Model in Real-Time Target
Hello, I am using a _SimPowerSystems_ part called *Three-Phase Fault* in a Simulink model which I am running on a Real-Time targ...
environ 10 ans il y a | 2 réponses | 0