photo

MathWorks Motor Control Blockset Team

Last seen: environ 2 mois il y a Actif depuis 2023

Followers: 0   Following: 0

Statistiques

All
MATLAB Answers

0 Questions
7 Réponses

File Exchange

4 Fichiers

RANG
4 774
of 300 786

RÉPUTATION
10

CONTRIBUTIONS
0 Questions
7 Réponses

ACCEPTATION DE VOS RÉPONSES
0.00%

VOTES REÇUS
1

RANG
7 483 of 21 091

RÉPUTATION
132

CLASSEMENT MOYEN
5.00

CONTRIBUTIONS
4 Fichiers

TÉLÉCHARGEMENTS
36

ALL TIME TÉLÉCHARGEMENTS
2596

RANG

of 171 031

CONTRIBUTIONS
0 Problèmes
0 Solutions

SCORE
0

NOMBRE DE BADGES
0

CONTRIBUTIONS
0 Publications

CONTRIBUTIONS
0 Public Chaîne

CLASSEMENT MOYEN

CONTRIBUTIONS
0 Point fort

NOMBRE MOYEN DE LIKES

  • 5-Star Galaxy Level 2
  • Personal Best Downloads Level 2
  • GitHub Submissions Level 3
  • Knowledgeable Level 1
  • First Answer
  • First Submission

Afficher les badges

Feeds

Afficher par

Réponse apportée
PMSM motor cannot start up when using launchpad F28379D + FOC in simulink
Run the example in open-loop control mode to validate the hardware setup and motor. The example has an open loop start-up. Modif...

environ 2 mois il y a | 0

Réponse apportée
示例《Sensorless Field-Oriented Control of PMSM Using DC Shunt Current Sensing》中,仿真和代码生成的相移方向是相反的,应如何理解?
Hello, thank you for the question. Your observation is correct. Hardware configuration is for rising edge but simulation plant l...

environ 2 mois il y a | 0

| A accepté

A soumis


Motor Control Using NXP™ Development Kits
Field-Oriented Control of Permanent Magnet Synchronous Motor Using NXP™ Development kits

3 mois il y a | 13 téléchargements |

5.0 / 5
Thumbnail

A soumis


Demos for Motor Control Deployment on Renesas Controllers
PMSM control examples using the Renesas motor control development kits.

7 mois il y a | 9 téléchargements |

0.0 / 5
Thumbnail

Réponse apportée
Sensorless Control with High Frequency Signal Injection at Low Speed
Please refer to the following document page: Initial Position Estimation and Field-Weakening Control of IPMSM Using Pulsating Hi...

9 mois il y a | 0

Réponse apportée
How to generate first value for Kp, Ki of PID in current controller
Please refer to the following document page: Estimate Control Gains and Use Utility Functions.

9 mois il y a | 1

Réponse apportée
In the BLDC motor block, a non-standard d'q' Transformation is used. Does this affect the values of L_d and L_q?
Thank you for providing your valuable feedback. The factor of π is a typographical error in the documentation and will be correc...

9 mois il y a | 0

A soumis


Motor Swap of PMSM Using Microchip MCS MCLV-48V-300W
Run any three-phase PMSM using Microchip MCS MCLV-48V-300W Development Board and dsPIC33AK128MC106 MC DIM

9 mois il y a | 4 téléchargements |

0.0 / 5
Thumbnail

A soumis


Demos for Motor Control Deployment on Microchip Controllers
PMSM control examples using the Microchip motor control development kit.

presque 2 ans il y a | 10 téléchargements |

0.0 / 5
Thumbnail

Réponse apportée
TI F28379D Launchpad Serial Communication Failure
In mcb_param_est_host_read, update the COM port in 3 blocks, Host Serial Setup, Host Serial Receive, Host Serial Transmit. You ...

plus de 2 ans il y a | 0

| A accepté

Réponse apportée
I want to make 'Deploying Motor Control Algorithms on Microchip dsPIC, PIC32, and SAM Controllers'. But MPLAB version is different. Could you give me the 3.50 version?
Hi, Please post a query at MPLAB Device Block page to check if it supports 3.50 version.

plus de 2 ans il y a | 0