Question
Create a surface with separate contours from other plots
I saved one contour from separate surfaces as a matrix of 3xn (each column is x, y and z (elevation)). I use plot3 for each con...
plus de 2 ans il y a | 1 réponse | 0
1
réponseQuestion
One window and two plots using command plot3
I think my code is OK, but I would like to show that my plots are using the same x axis. Here is my code: set(gcf,'position',[...
environ 5 ans il y a | 1 réponse | 0
0
réponseQuestion
For one equation ==> Warning: Explicit solution could not be found
Hi, I've written 4 kind of codes to solve lam: %-----------1---------------- _syms lam K4 Vw; S=solve((119/lam - 9)*ex...
environ 11 ans il y a | 1 réponse | 0
0
réponseQuestion
Mode accelerator in Simulink and Windows 7 64-bits
Hi,... I have a model in Simulink which can run in normal model, however, in accelerator mode or real-time it doesn't work. It ...
plus de 13 ans il y a | 1 réponse | 0
1
réponseHow to test my filter design?
You can design a filter with the same specifications using FDAtool in Simulink...Then you can generate a signal to try the filte...
plus de 13 ans il y a | 0
| A accepté
simulation of a power system..
You can use a "Three-Phase V-I Measurement" block from... it could be configurated depending on your necessities. You can connec...
plus de 13 ans il y a | 0
Maximum step size warning in Simulink
What kind of simulation you are doing?
plus de 13 ans il y a | 0
Question
Signal processing with high harmonic content... Fourier... Filter???
Hi, I have a voltage (v) and current (i) signals with high harmonic content. Also these signals are generated by a variable freq...
plus de 13 ans il y a | 1 réponse | 0
1
réponseQuestion
How can I define some initialization commands in a s-function block in Simulink depending on a declarated variable from the Matlab command window ?
Hi, I have a subsystem masked in Simulink which contains initialization commands that are used depending on a declared variable ...
presque 14 ans il y a | 1 réponse | 0
1
réponseQuestion
Protecting a Simulink block with a password
I want to protect a Simulink block (subsystem masked) with a password, so that nobody can open the block or modify the initializ...
presque 14 ans il y a | 2 réponses | 0