Statistiques
RANG
25 539
of 292 677
RÉPUTATION
1
CONTRIBUTIONS
10 Questions
4 Réponses
ACCEPTATION DE VOS RÉPONSES
60.0%
VOTES REÇUS
1
RANG
of 19 931
RÉPUTATION
N/A
CLASSEMENT MOYEN
0.00
CONTRIBUTIONS
0 Fichier
TÉLÉCHARGEMENTS
0
ALL TIME TÉLÉCHARGEMENTS
0
CONTRIBUTIONS
0 Publications
CONTRIBUTIONS
0 Public Chaîne
CLASSEMENT MOYEN
CONTRIBUTIONS
0 Point fort
NOMBRE MOYEN DE LIKES
Feeds
A résolu
Times 2 - START HERE
Try out this test problem first. Given the variable x as your input, multiply it by two and put the result in y. Examples:...
presque 7 ans il y a
Question
simulink output in a parfor loop
Hi all, I'm running a model and need to sweep through a lot of parameters so I am using the parallel computing toolbox. I usu...
plus de 9 ans il y a | 1 réponse | 0
0
réponseQuestion
Pneumo-Hydraulic Actuator mechanical ports
I just discovered the Pneumo-Hydraulic Actuator which seems great for my application as I was previously using a gas accumulator...
plus de 9 ans il y a | 1 réponse | 0
1
réponseQuestion
Pneumo-Hydraulic Actuator ports
Hi, I was just wondering why the Pneumo-Hydraulic Actuator does not have a mechanical translational conserving port associated ...
plus de 9 ans il y a | 1 réponse | 0
1
réponseError in port widths or dimensions
Thanks Mike, You're right, it should be xo and not x0, stupid mistake! Also I found out that the output variable need to be in...
presque 10 ans il y a | 0
Question
Error in port widths or dimensions
Hi, I do get the following error: Caused by: Error using sldebugui (line 77) Errors occurred during pars...
presque 10 ans il y a | 2 réponses | 0
2
réponsesQuestion
Gas accumulator initial pressure
Hi, I'm running a model with a gas accumulator which is connected to several other hydraulic block (pipeline, hydraulic cylin...
plus de 10 ans il y a | 1 réponse | 0
1
réponseQuestion
State Space with variable parameters
Hi everyone, I'm using Simulink and a State Space Block. I would like to implement some parameters (A, B, C and D) variable at ...
plus de 11 ans il y a | 1 réponse | 0
1
réponseQuestion
Constant pressure source inferior to Pa
It appears that all pressure in simhydraulics are defined as gauge pressure. Is there any way to set a pressure source in the m...
environ 12 ans il y a | 1 réponse | 0
0
réponseUsing structures as input of the model with parallel computing
Can anyone help on this topic ?
plus de 12 ans il y a | 0
Using structures as input of the model with parallel computing
Thanks for the reply TAB. The problem is I think I have to define my properties in the model workspace as I am using parrallel ...
plus de 12 ans il y a | 0
Question
Using structures as input of the model with parallel computing
Hi everyone, I'm currently using structure of constants as an input of simulink blocks in my model. The only way I was able t...
plus de 12 ans il y a | 4 réponses | 1
4
réponsesInput of Simulink block used in vector
Any clue someone ?
plus de 12 ans il y a | 0
Question
Input of Simulink block used in vector
Hi all, I'm using a constant input (actually a strcuture of constant values implemented via a BUS) in a simulink block and I ...
plus de 12 ans il y a | 1 réponse | 0
1
réponseQuestion
Rename BUS
Hi, I am trying to generate a BUS from a Matlab structure to feed in a Simulink block. I am using this function: FA.cog ...
plus de 12 ans il y a | 2 réponses | 0