Statistiques
RANG
25
of 296 933
RÉPUTATION
10 272
CONTRIBUTIONS
14 Questions
4 054 Réponses
ACCEPTATION DE VOS RÉPONSES
71.43%
VOTES REÇUS
1 552
RANG
of 20 421
RÉPUTATION
N/A
CLASSEMENT MOYEN
0.00
CONTRIBUTIONS
0 Fichier
TÉLÉCHARGEMENTS
0
ALL TIME TÉLÉCHARGEMENTS
0
CONTRIBUTIONS
0 Publications
CONTRIBUTIONS
0 Public Chaîne
CLASSEMENT MOYEN
CONTRIBUTIONS
0 Point fort
NOMBRE MOYEN DE LIKES
Feeds
Tally Instances of Negative Numbers in an Array (for loop)
A=load() returns A as a structure, not a typical matrix. If you make A an matrix, this code would work if you make the following...
1 jour il y a | 0
isnan to conver nan to zero in a table
T is an object of the class "table". You can't apply isnan() on it directly. Try the 'TreatAsMissing' option of the readtable() ...
1 jour il y a | 0
Is there a way to extract a list from "PV Array.ModuleName.Enum" to view the solar module data more efficiently?
Should be BlockDialogParameters.ModuleName.Enum or getfield(BlockDialogParameters.ModuleName,'Enum')
1 jour il y a | 0
Plot RGB triplets from a matrix as markers 'o'
Use 'color' to specify color in plot() x = linspace(0,10,10); y = linspace(0,10,10); xlabel('X-axis'); ylabel('Y-axis'); ax...
5 jours il y a | 0
What is the max number of digits allowed for a base 2 number?
The default data type in MATLAB is "double", which means 64 bits. When used to represent a base 2 number, its maximum value is 2...
8 jours il y a | 0
How to set Simulink block parameters using an absolute model path
The "absolute model path" of a block starts with the name of the model, not including the file folder where the model file is st...
13 jours il y a | 0
| A accepté
How to output text to Command Window if signal changes from 0 to 1 in Simulink
You might want to do that, but MATLAB and Simulink are quite different. I don't think you can do that because disp() or fprint...
18 jours il y a | 0
I can't download Matlab R2022a release or earlier release
I can see many versions on this link. https://www.mathworks.com/downloads/
19 jours il y a | 0
How to change const variable during simulink runtime
While the simulation is running, if you double click the Constant block, change its value from one numeric value to another (e.g...
21 jours il y a | 0
Initial condition from external source for discrete integration diuring runtime
The value of "mec_init_pos" could be constant or dynamic, but in this case, only its value at the begining of the simulation (e....
26 jours il y a | 1
| A accepté
Function Call Trigger Problem
This "Outport" block seems to output a function call trigger. The message tells you what type of block can receive this signal. ...
26 jours il y a | 0
A few basic Simulink/Simscape questions
run forever (tstop = inf) Yes. Set the simulation stop time to be inf store the trailing 10000 points Yes. Limit the data poi...
27 jours il y a | 0
| A accepté
How the Delay one step block and stop time ( simulation time) infuence each other on simulink?
If you don't specify the step size or it is auto, the step size is automatically adjusted, influnced by simulation stop time and...
29 jours il y a | 0
Simulink model output heavily dependent on relative tolerance
Not typical but is for a stiff system. Choose a stiff solver. https://www.mathworks.com/help/matlab/math/solve-stiff-odes.html
29 jours il y a | 0
Issue in creation of test harness of a Simulink state in stateflow or creation of harness of a subsystem present in simulink state of stateflow.
I don't think a "system under test" can be a "state" in a state chart. A typical "system under test" has inputs, while a "state"...
environ un mois il y a | 0
Hello, can MATLAB solve equations like the one below? I mean, can MATLAB find the conditions for z that satisfy this relationship, instead of just numerical solutions?
https://www.mathworks.com/products/symbolic.html
environ un mois il y a | 0
| A accepté
Generate signal according to the the rising edges of two pulse generators in simulink.
A triggered subsystem shoud suffice. https://www.mathworks.com/help/simulink/slref/triggeredsubsystem.html
environ un mois il y a | 0
Matlab & Simulink crash at 2nd model run
After first run, execute "clear mex" or "clear functions" in MATLAB Command Window to see if it makes a difference.
2 mois il y a | 0
Avoid reuse of local variables in Embedded coder
That is probably not the correct option. You should try to disable the "Reuse local block outputs" option. https://www.mathwor...
2 mois il y a | 0
Switch multiport switch inputs based on time and order from user
There are many ways to do it. The easiest or most flexible way to do it is probably by using a MATLAB Function block. Use a Cloc...
2 mois il y a | 0
Attempting to turn off Dynamic Memory allocation but struggling to set variable size upper bound
Try allocating the variable in one shot, e.g. obj=struct('x',num2cell(rand(1,1000)))
2 mois il y a | 0
Can one Function call Trigger Multiple Subsystems?
Function-Call Split https://www.mathworks.com/help/simulink/slref/functioncallsplit.html
3 mois il y a | 0
| A accepté
运行s-function Output argument "sys" (and possibly others) not assigned a value in the execution with "ctrl>mdlOutputs" function.
Probably a typo at the last line of this code below. Should be 'sys', not 'sym'. Also need to add a line 'end' to finish this fu...
4 mois il y a | 1
my for loop stop after the first valid number has been found how do i fix this
Use "result_1", no need to create "answer_1" numbers=1:100; result_1=[]; for i =1:numel(numbers); num=numbers(i); i...
6 mois il y a | 0
| A accepté
hi i started the matlab onramp course and im stuck on this further practice question i wld appreciate if anyone cld help me or even give an hint
density=10:10:100 index=[1 3 6] SelectedDensityValue=density(index)
6 mois il y a | 0
Questions regarding Unit Delay block initial condition and model recompilation
Use Simulink.Parameter Specify its storage class as "ImportFromFile" and specify a HeaderFile name. When the code is generated...
6 mois il y a | 0
Why am I getting a computed maximum size is not bounded error in a MATLAB Function block in Simulink R2021a even when using assert?
The Simulink diagnostic is probably not designed to read the assert() function. The proper way for this is to define those data...
6 mois il y a | 0
How do I use the unit per mille in Simulink parameters and ports?
It is "m" for "milli". "mille" means "a thousand", that is "k" for "kilo".
6 mois il y a | 0
switching of svpwm is not working . it is not showing staircase mode in scope
To convert radians to degree, the Gain should be 180/pi. You had it as pi/180. That seems to be the cause. The logic seems corr...
6 mois il y a | 0
| A accepté
how to write a program combininb name and age?
No Switch statement is needed. This practice is to get the input and put it in the right format. help input help sprintf
6 mois il y a | 1