Community Profile

photo

Rodney Tan


UCSI University

Last seen: 4 jours il y a Actif depuis 2015

My research area are Renewable Energy, Energy Storage, Power Electronics and Power System

Statistiques

All
  • MATLAB Mini Hack Participant
  • Triathlon Participant
  • Revival Level 1
  • Knowledgeable Level 2
  • Solver
  • Speed Demon
  • Editor's Pick
  • Top Downloads 2022
  • Top Downloads 2021
  • Top Downloads 2020
  • Personal Best Downloads Level 5
  • First Review

Afficher les badges

Content Feed

A soumis


Flicker Waveform Generator
Flicker waveform generator implemented based on IEC 61000-4-15 Annex B for flickermeter test.

3 jours il y a | 1 téléchargement |

Thumbnail

A soumis


MPPT Interactive Demo Particle Swarm Optimization
MPPT Interactive Demo Particle Swarm Optimization, demonstrates how the PSO algorithm track the maximum power of a PV panel.

9 jours il y a | 19 téléchargements |

Thumbnail

A soumis


Boost Converter with Closed-Loop Control Typhoon HIL Replica
Boost Converter with Closed-Loop Control Replication from Typhoon HIL Control Center Example

environ 2 mois il y a | 9 téléchargements |

Thumbnail

A soumis


EV AC Charger Load Double Tuned Harmonic Filter
This simulink model simulate EV on-board AC charger with 7kW per EV at 400V distribution line with double tuned harmonic filter....

3 mois il y a | 16 téléchargements |

Thumbnail

A soumis


Electric Railway AC 25kV Harmonic Filter
This model demonstrates how passive single tuned filter bank is used to mitigate 3rd, 5th, 7th, 9th and 11th order harmonic on c...

3 mois il y a | 8 téléchargements |

Thumbnail

A soumis


Hibikinada Wind Turbine DFIG 1.5 MW
Modeling of single 1.5 MW DFIG wind turbine by General Electric (GE 1.5sle) connected to 22 kV grid at Hibikinada EcoTown, Kitak...

4 mois il y a | 12 téléchargements |

Thumbnail

A soumis


Generator Differential Protection Principle
This Simulink model demonstrates differential protection for generator by measuring its differential current

5 mois il y a | 8 téléchargements |

Thumbnail

A soumis


Overcurrent & Earth Fault Relay Protection Switchgear
Combined Overcurrent & Earth Fault Relay integrate into protection switchgear for distribution line protection

6 mois il y a | 15 téléchargements |

Thumbnail

A soumis


Island Microgrid Wind Turbine 150 kW
A microgrid model consists of a 150 kW wind turbine and a genset supplying a small island load

7 mois il y a | 29 téléchargements |

Thumbnail

A soumis


BESS Protection AC DC
This model demonstrates the use of AC and DC circuit breakers to protect grid connected BESS from internal and external fault.

8 mois il y a | 12 téléchargements |

Thumbnail

A soumis


Home Battery Energy Management System
Home Battery Energy Management System allows the user to set PV, battery capacity and computes grid energy usage.

8 mois il y a | 39 téléchargements |

Thumbnail

A soumis


Simplified Power Plant Generator to Transmission Grid
This model demonstrates power plant synchronous generator connected to 500kV transmission grid.

10 mois il y a | 6 téléchargements |

Thumbnail

A soumis


Brayton Cycle Interactive Demo
This demo plot all 4 stages of ideal brayton cycle on T-s diagram and computes its thermal efficiency and mechanical power.

11 mois il y a | 13 téléchargements |

Thumbnail

A soumis


Rankine Cycle Interactive Demo
This demo plot all 4 stages of ideal Rankine cycle on T-s diagram and computes its thermal efficiency and mechanical power

11 mois il y a | 15 téléchargements |

Thumbnail

A soumis


Electric Railway AC 25kV Traction Power Supply System
This model demonstrates a simplified AC 25kV electric railway traction Power supply system to drive a 1kV JR EH800 train load

environ un an il y a | 23 téléchargements |

Thumbnail

A soumis


ML8511 UV sensor Module
ML8511 UV Sensor Module was modeled based on LAPIS Semiconductor product datasheet.

environ un an il y a | 2 téléchargements |

Thumbnail

A soumis


PR Controller
This demonstrates the advantage of PR controller over PI controller for controlling periodic parameter.

environ un an il y a | 39 téléchargements |

Thumbnail

A soumis


BPW34 Photodiode Solar Irradiance Sensor
Modeling BPW34 photodiode as Solar Irradiance Sensor with sensitivity about 0.2mV / W/m^2 with 43 ohm resistor

environ un an il y a | 5 téléchargements |

Thumbnail

A soumis


MOSFET Switching Waveform Test Bench
MOSFET Switching waveform test bench plots the Ids, Vds, Vgs, and power loss switching time waveform characteristics.

plus d'un an il y a | 10 téléchargements |

Thumbnail

A soumis


MPPT Interactive Demo Perturb & Observe
MPPT Interactive Demo Perturb & Observe, demonstrates how the P&O algorithm track the maximum power of a PV panel.

plus d'un an il y a | 17 téléchargements |

Thumbnail

A soumis


Transistor Thermal Performance Model
This model shows how transistor power dissipation affects the heat generated from junction to case to heatsink.

plus d'un an il y a | 5 téléchargements |

Thumbnail

A soumis


Transistor Heat Transfer Interative Demo
This script & Simulink model demonstrates heat generated by power dissipation at transistor junction and its heat transfer to th...

plus d'un an il y a | 7 téléchargements |

Thumbnail

A soumis


Standard Cell PV Panel
This PV panel consists of 60 or 72 standard cells with 3 bypass diodes for partial shading study

plus d'un an il y a | 8 téléchargements |

Thumbnail

A soumis


Half-Cut Cell PV Panel
A Half Cut Cell PV Panel model is made up of 6 groups of half-cut PV cells and 3 bypass diodes connected in series parallel.

plus d'un an il y a | 4 téléchargements |

Thumbnail

A soumis


Adafruit Analog UV Light Sensor Breakout Model
Analog UV Light Sensor Breakout Board was modeled based on Adafruit product specifications found at https://www.adafruit.com/pro...

plus d'un an il y a | 2 téléchargements |

Thumbnail

A soumis


GUVA-S12SD Photodiode Model
GUVA-S12SD photodiode was modeled based on Genuine UV Technology datasheet. It is widely used for UV Intensity and UV Index moni...

plus d'un an il y a | 4 téléchargements |

Thumbnail

A soumis


Earth Fault Relay 51N/50N
This relay block combine Earth Fauth Relay and Instantaneous Relay (ANSI/IEEE C37.2 device number 50N and 51N)

plus d'un an il y a | 9 téléchargements |

Thumbnail

A soumis


Wiring Cable
Wiring Cable allows the user to determine the cable size based on conductor cross sectional area in mm^2 for a given installatio...

plus d'un an il y a | 5 téléchargements |

Thumbnail

A soumis


BESS Moving Average Control for PV Plant Output Smoothing
The model demonstrates battery energy storage system with moving average control is used to smooth out the PV plant intermittent...

plus d'un an il y a | 16 téléchargements |

Thumbnail

A soumis


Single Tuned Passive Harmonic Filter 4 Electric Railway TPSS
This model consists of an Electric railway DC 750V Traction Power Supply System (TPSS) fed from 33kV for harmonic distortion stu...

plus d'un an il y a | 4 téléchargements |

Thumbnail

Charger plus