Paul Urban
MathWorks
Followers: 0 Following: 0
Statistiques
RANG
1 285
of 295 527
RÉPUTATION
54
CONTRIBUTIONS
0 Questions
26 Réponses
ACCEPTATION DE VOS RÉPONSES
0.00%
VOTES REÇUS
5
RANG
of 20 242
RÉPUTATION
N/A
CLASSEMENT MOYEN
0.00
CONTRIBUTIONS
0 Fichier
TÉLÉCHARGEMENTS
0
ALL TIME TÉLÉCHARGEMENTS
0
CONTRIBUTIONS
0 Publications
CONTRIBUTIONS
0 Public Chaîne
CLASSEMENT MOYEN
CONTRIBUTIONS
0 Point fort
NOMBRE MOYEN DE LIKES
Feeds
OSLC Server support for Matlab
As of R2021a you can now use a command-line OSLC client in MATLAB to communicate with OSLC providers. You can use the client to ...
11 mois il y a | 0
How to modify signal editor active scenario from the test assessment (or test manager)?
Have you tried using the Test Manager? There are a couple of ways to do this thru the Test Manager. You can open test manager w...
plus d'un an il y a | 1
Is there a way to change order of TestCases in sltest.testmanager.TestSuite programmatically?
You can use the moveTest api’s starting with R2020b release to move tests with the following. We will request the documentation...
environ 2 ans il y a | 0
Integrating Simulink Requirement with Jama
Integrating with Jama Connect can be done through import and export of ReqIF. This would be through the Jama Data Exchange. AP...
environ 2 ans il y a | 0
Do the "Simulink Test" toolbox work with dSPACE TargetLink models?
It should be possible to import the TargetLInk code into a SIL or PIL block and then test this with Simulink Test. There is a v...
environ 2 ans il y a | 0
| A accepté
Requirements Toolbox: Recommended workflow for performing reviews of requirements and test-cases
The requirements themselves would need to be reviewed by another engineer. One option to keep track of the status of the require...
environ 2 ans il y a | 1
| A accepté
Matlab Requirements Toolbox capabilities
Hi @Esin I will try to answer some of your questions. I'm not sure exactly what you mean reach history, but requirements ar...
environ 2 ans il y a | 0
Why such a large '.dmr' files (e.g. 50G) are generated when running a test harness ?
More information is needed to investigate this, please contact MathWorks Technical Support at this link: MathWorks Technical Sup...
environ 2 ans il y a | 0
Manipulate requirements verfied status ?!
There is an example here on how to link results from an external source https://www.mathworks.com/help/slrequirements/ug/int...
plus de 2 ans il y a | 0
How do I merge two linkage files for simulink requirements?
You can use the Three Way Merge that is on File Exchange: This is compatible with R2018b and later https://www.mathworks.com...
plus de 3 ans il y a | 0
| A accepté
How to access previous revisions of a requirement in Simulink Requirements
There isn't a way to do this directly but it is possible to compare versions of the requirement set file under version control t...
presque 4 ans il y a | 0
| A accepté
Simulink Test does not execute test iterations
This should not occur unless there are in fact duplicates. It may have something to do with the file organization - but it's har...
presque 4 ans il y a | 1
Difference between Simulink diagnostics and Simulink Design Verifier error checking?
Simulink Design Verifier can detect these errors before simulation by using formal methods to analyze the model for errors such ...
environ 4 ans il y a | 1
| A accepté
OSLC Server support for Matlab
Currently MATLAB and Simulink are not OSLC consumers or producers. Simulink Requirements uses OSLC API’s from DOORS Next Genera...
plus de 4 ans il y a | 0
| A accepté
Test Manager Input Starting of the Second Row
It is possible to specify a range of cells to use in the Test Manager. In the inputs section of the Test Manager, select the e...
plus de 4 ans il y a | 0
| A accepté
Simulink test multiple sequences for harness
Yes it is possible to put multiple test sequences inot a test harness. You can use variants to control which Test Sequence is ...
plus de 4 ans il y a | 0
Custom naming convention - enforcement (na_0035: Adoption of naming conventions) using simulink check
na_0035: Adoption of naming conventions is not a checkable guideline. This is more of a general best practice to state that you...
presque 5 ans il y a | 0
| A accepté
Does baseline criteria give expected output?
There are multiple ways to capture expected outputs for a test case. In addition to Excel there are Test Assessment Blocks, ve...
presque 5 ans il y a | 0
how to add requirements from docx or xlsx file to simulink requirements? i also tried help section of (Import Requirements from Third-Party Tools )
Import from Word or Excel is not supported on Linux since they are not supported by Microsoft on Linux. You could import the Wo...
presque 5 ans il y a | 0
save directory of Externally-saved test harnesses
When creating an external harness the path where the harness is stored defaults to the current working directory. There is an o...
presque 5 ans il y a | 0
| A accepté
Signal did not align
From the information given there could be a few possibilities for the error. More information is needed but here are a couple t...
presque 5 ans il y a | 1
| A accepté
To create Requirement links, I drag and drop on the port/subsystem but the badge does not appear
When selecting the requriement to start the drop operation do this from the left most column in the Requirements browser, the I...
environ 5 ans il y a | 0
Is there a standard plug-in for JAMA Requirements management to link Simulink Requirements to JAMA?
Jama can exchange requriements using the ReqIF standard through the Jama Data Exchange. Simulink Requirements can import the r...
environ 5 ans il y a | 0
Why can't I see the Coverage Option under Analysis menu even though I have the Verification and Validation License checked out
For more information about the Simulink Verification and Validation transition please see this page: https://www.mathworks.com...
plus de 5 ans il y a | 0
"Selection for Simulink" Widget in IBM Doors NG
To set up the integration wtih DOORS Next Generation follow these steps described in the help: Configure RMI for IBM Rational...
plus de 5 ans il y a | 0
Is it possible to merge Simulink requirement .slreqx files
When importing a reference from a another tool the there is an Update operation that can be used to bring in changes to the requ...
environ 6 ans il y a | 0
| A accepté
A résolu
Times 2 - START HERE
Try out this test problem first. Given the variable x as your input, multiply it by two and put the result in y. Examples:...
plus de 8 ans il y a