Analyze Multidimensional Signal Data
When you log or import multidimensional signal data with fixed dimensions into the Simulation Data Inspector, you can choose to view and analyze data as:
A single signal with multidimensional sample values
A set of signals with scalar sample values: one signal, called a channel, for each element of the multidimensional data
Variable-sized signals are always represented as a single signal with multidimensional values.
When the multidimensional data is frame-based, you can also use the Simulation Data Inspector to remove the buffering from each frame.
You can control how you view and analyze multidimensional signal data using the Record block or the Simulation Data Inspector. When you change the representation of a multidimensional signal in the Record block, the change is reflected in the Simulation Data Inspector and vice versa.
Convert Representation of Multidimensional Data
The way the Simulation Data Inspector initially represents a multidimensional signal with fixed dimensions depends on the number of elements in each sample of the signal. By default:
Signals with samples that contain fewer than five elements are represented as channels.
Signals with samples that contain five or more elements are represented as a single signal with multidimensional sample values.
Note
Variable-sized signals are always represented as a single signal with multidimensional sample values and cannot be converted.
When the default behavior for a signal with fixed dimensions does not provide the representation you need for your analysis, you can convert the representation from a single signal to channels or from channels to a single signal.
For example, consider this output from a model that creates two composite signals using Mux blocks:
Large Mux
contains five elements and is displayed as a single signal by default.Small Mux
contains two elements and is displayed as two channels by default.
The run includes one row for the Large Mux
signal and three rows for
the Small Mux
signal. By default, the Simulation Data Inspector groups
signals by data hierarchy, so one row groups the signals for each channel in the
Small Mux
signal, and each channel has a row.
Dimensions are indicated as part of the signal name in the table of signals under each run.
When a multidimensional signal is represented as a single signal with multidimensional sample values, the signal name row indicates the dimensions.
When a multidimensional signal is represented as channels, the grouping row indicates the dimensions.
To convert the representation of a signal with multidimensional data, you can click the
dimensions and select an option from the menu. For example, to convert the Large
Mux
signal to channels, click the dimensions, 5
, and select
Convert to channels.
To convert the Small Mux
signal to a single signal, click the
dimensions, 2
, for the grouping row and select Convert to
multidimensional signal.
When you convert a signal from channels to a single signal, any plotted channels are cleared from the view because the signals for the channels no longer exist.
You can also convert the representation of multidimensional signals in the Simulation
Data Inspector programmatically using the expand
and
collapse
functions.
Plot Multidimensional Signal Data
Most visualizations in the Simulation Data Inspector, including time plots, XY plots, maps, and sparklines, only support plotting scalar signals. To plot data from a multidimensional signal on one of these visualizations, convert the signal to channels. You can use the conversion menus that you access by clicking the signal dimensions or the menu that appears on a subplot that does not support multidimensional data when you try to plot the signal.
For example, if you try to plot the Large Mux
signal on a time plot,
the menu gives you the option to change the active subplot to an array plot, which does
support multidimensional data, or to convert the representation of the signal.
To view multidimensional data, use the array plot in the Simulation Data Inspector. The array plot supports scalar and multidimensional signals, including variable-size signals. You can add an array plot to the subplot layout using the menu that appears when you try to plot a multidimensional signal on a plot that only supports scalar signals or using the Visualization Gallery. For more information about using the array plot, see View Multidimensional Signals Using the Array Plot. The Record block does not support the array plot.
Only time plots support plotting signals programmatically. You can plot channel data on
a time plot programmatically. You cannot plot data for a signal with multidimensional sample
values programmatically. Use the expand
function to convert a single multidimensional signal to channels, which you can plot on a
time plot programmatically using the plotOnSubPlot
function.
Compare Multidimensional Signals
By default, when you compare multidimensional signals represented as a single signal or runs that contain multidimensional signals represented as a single signal, the Simulation Data Inspector converts the multidimensional signal to channels and computes a comparison result for each channel. The conversion happens for the comparison only and does not affect the way the signal is represented on the Inspect pane. The Simulation Data Inspector does not support comparing variable-size signals or signals with multidimensional sample values.
If you do not want to compute comparison results for the channels in multidimensional signals, you can configure comparisons to skip multidimensional signals instead of computing the channel results. On the Compare pane, click Options, then clear Expand multidimensional channels.
Before R2024b: Click More to access global tolerance and constraint options.
You can also configure whether programmatic comparisons compute results for
multidimensional signals using the Simulink.sdi.compareRuns
function with the ExpandChannels
name-value argument.
Convert Representation of Frame-Based Data
Some applications buffer several samples of a signal into a frame to process with a single computation instead of processing each sample in the frame separately. When you work with frame-based signals, you can analyze the data frame by frame, or you can remove the buffering and analyze the signal without the frames.
You can remove frame buffering from signals logged to the Simulation Data Inspector using the menu that appears when you click the dimensions next to a multidimensional signal or the menu that appears when you try to plot multidimensional data on a plot that only supports scalar data.
For example, consider this run created by logging data for the analog to digital
converter output in the model sfcndemo_frame
. The model buffers the
samples into a frame and performs a discrete Fourier transform on each frame. To remove the
frame buffering in the Simulation Data Inspector, click the dimensions for the signal,
64
×2
, and select Convert
frames. The conversion interprets each sample as 64 evenly spaced samples with
dimensions 1
-by-2
. Because the unbuffered signal only
contains two elements, conversion also displays the results as separate channels with scalar
sample values.
You can also convert the frames for a frame-based signal in the Simulation Data
Inspector programmatically using the convertToFrames
function. The Simulation Data Inspector does not support
converting frames for imported data.
When you log frame-based data from a model, you can control how the data is logged by
specifying the Input Processing setting for the logged signal in the
model using the Instrumentation
Properties dialog box or the Simulink.sdi.setSignalInputProcessingMode
function. You can configure the
input processing for the signal as frame-based or sample-based.
Sample-based — The logged data retains the buffering, and each sample of the logged signal represents a frame. The Simulation Data Inspector interprets the data as a multidimensional signal, where each element of a sample represents a separate channel.
Frame-based — Logging removes the buffering and treats each column in the samples as a separate channel.
When you log frame-based signals as sample-based, you can still convert the frames in the Simulation Data Inspector after simulation.