Clear a persistent variable in a MATLAB Fcn block as serial object

3 vues (au cours des 30 derniers jours)
Marco
Marco le 26 Fév 2014
Hello! I am using following code for read data from serial port:
function y = fcn(u)
coder.extrinsic('only3')
coder.extrinsic('strncmp')
coder.extrinsic('serial', 'fopen','fread')
coder.extrinsic('get')
persistent s a b
y = uint8(zeros(2,1)); %signal is an uint8
if isempty(s)
% only do this the first time
s = serial('COM12','Terminator','', 'InputBufferSize', 1024);
a = '000';
b = false;
a = only3(get(s,'status'));
b = strncmp(a,'clo',3);
switch double(b)
case 1
fopen(s);
otherwise
fclose(s);
end
end
y = uint8(fread(s,[2 1],'uint8'));
Where 'only3' is my function that takes only the first 3 chars from a string. The problem is that communication does not terminate with simulation stopping. Switch case has no effect (I thought that it shuts down reading after an other run). How can I clear persistent variable 's' and reset the block after stopping?

Réponses (3)

Paul
Paul le 26 Fév 2014
  1 commentaire
Marco
Marco le 27 Fév 2014
I tried that but it returns an error:
Open failed: Port: COM12 is not available. No ports are available. Use INSTRFIND to determine if other instrument objects are connected to the requested device. Block Gyro/Serial Read (#59) While executing: State During Action
where #59 points to 'fopen(s)' command

Connectez-vous pour commenter.


Friedrich
Friedrich le 27 Fév 2014
Modifié(e) : Friedrich le 27 Fév 2014
Hi,
A MATLAB FCN Block is a bad idea here. Better would be a MATLAB LVL 2 S-function because you can better control your serial port. In the mdlStart you create your serial object and later in the mdlTerminate you close it propperly. In the mdlOutputs you calculate the signal as usual.
  6 commentaires
Marco
Marco le 28 Fév 2014
Are you saying that I have to modify mdlInitializeSizes section as:
function [sys,x0,str,ts]=mdlInitializeSizes(stime)
global s
s = serial('COM12');
fopen(s)
sizes = simsizes;
sizes.NumContStates = 0;
sizes.NumDiscStates = 0;
sizes.NumOutputs = 2;
sizes.NumInputs = 0;
sizes.DirFeedthrough = 1;
sizes.NumSampleTimes = 1; % at least one sample time is needed
sys = simsizes(sizes);
x0 = [];
str = [];
ts = [stime 0];
end
??? In this way it should call object creation and opening only one time, is it?
Friedrich
Friedrich le 3 Mar 2014
Yes. You open the serial port in the mdlInitializeSizes and close it in the mdlTerminate.

Connectez-vous pour commenter.


Ryan Livingston
Ryan Livingston le 2 Avr 2014
Another thought could be to use the serial port I/O blocks directly in Simulink. See the Blocks heading here:
I am not too familiar with them, but they may facilitate a simpler interface to your hardware.
These could perform the I/O and then you could process the data using the method of your choosing.

Catégories

En savoir plus sur Simulink Functions dans Help Center et File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by