Effacer les filtres
Effacer les filtres

time aligning two signal at different sample rates

29 vues (au cours des 30 derniers jours)
Bran
Bran le 13 Août 2014
Most of the techniques I have discovered to time align two signals requires them to be sampled at the same rate. I am aware of the resample() function on matlab but I have a signal sampled at 60 Hz and the other at 200 Hz and I must of course use a rational fraction. Is there a way around this?
  1 commentaire
dpb
dpb le 13 Août 2014
Around what, specifically? What do you think you want to resample to?

Connectez-vous pour commenter.

Réponses (1)

Star Strider
Star Strider le 13 Août 2014
According to the documentation on resample, p and q simply have to be integers, and 60 and 200 meet those requirements. It is probably more reliable to downsample the signal sampled at 200 Hz to 60 Hz sampling.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by