Dear Mathworks Support,
How to set stator-rotor turns ratio of an induction motor (wound rotor)?
Dan

Réponses (1)

Sandip Kumar
Sandip Kumar le 7 Oct 2014
I understand you are referring to this Asynchronous machine:
If so, the stator-rotor turn ratio is captured in the resistance and inductance of the Stator and Rotor.
They should follow the following equation:
Rr' = a^2 * Rs; Llr' = a^2 * Lls;
hence, mention your resistance and inductance accordingly.
Thanks, Sandip, MathWorks
  1 commentaire
Nguyen Huu Nam
Nguyen Huu Nam le 5 Oct 2017
In Matlab simulink usely Llr' = Lls, that's mean a = 1 ? But Rr' no equal Rs Thanks and best regard