impact of zero sequence inductance when applied pmsm model

8 vues (au cours des 30 derniers jours)
adhavan d
adhavan d le 30 Août 2023
Commenté : adhavan d le 28 Sep 2023
how to identifid impact of zero sequence inductance where is applied in ipmsm model in delta connection.

Réponse acceptée

Sabin
Sabin le 27 Sep 2023
If the delta-wound option is selected, then is no longer valid that the ia+ib+ic=0. Hence the external circuit can drive an out-of-balance set of currents. The impact of zero sequence inductance will depend on the external circuit. Considering that v0=Rsi0+L0(di0/dt) we can conclude that zero sequence inductance will have an impact in the transient regime such as sudden changes in load and can help to dampen the oscillations. I hope this helps.

Plus de réponses (0)

Communautés

Plus de réponses dans  Power Electronics Control

Produits


Version

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by