Design a low pass filter using kaiser window
Afficher commentaires plus anciens
I need to setup a FIR filter for a signal with pass band cutoff 3.2 Hz, stop band cutoff 4.8 Hz, pass band ripple 0.1 dB, stop band attenuation 44 dB and sample frequency 16 Hz
After reading the documentation I tried this. Is the implementation correct?
[n,Wn,beta,ftype] = kaiserord([3.2 4.8],[1 0],...
[0.1 44],16);
b = fir1(n,Wn,ftype,kaiser(n+1,beta),'noscale');
c = kaiserord([3.2 4.8],[1 0],[0.1 44],16,'cell');
bcell = fir1(c{:});
hfvt = fvtool(b,1,bcell,1);
legend(hfvt,'b','bcell');
Réponse acceptée
Plus de réponses (1)
Star Strider
le 16 Déc 2016
1 vote
For what it’s worth, it seems to me to do what you designed it to do. In the fvtool GUI, you need to open the ‘Analysis’ tab and enter your sampling frequency (the last item in the drop-down menu) to verify the frequencies of the passband and stopband.
2 commentaires
Gehan Kavinda
le 16 Déc 2016
Modifié(e) : Gehan Kavinda
le 16 Déc 2016
Star Strider
le 16 Déc 2016
The frequencies you calculated from the radian frequencies are approximately correct (you rounded them to the nearest 0.1). By that criterion, the filter is correct. I don’t recognise the notation of ‘Ap’ and ‘Aa’, so I assume you interpreted them correctly. (I can’t find my copy of Antoniou just now.) Your filter has about 40 dB stopband ripple and about 20 dB stopband attenuation. I didn’t specifically measure the passband ripple, but it looks correct.
Catégories
En savoir plus sur Kaiser dans Centre d'aide et File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!