Power gui problem help
1 vue (au cours des 30 derniers jours)
Afficher commentaires plus anciens
mitesh kelaskar
le 6 Mar 2020
Déplacé(e) : Sabin
le 4 Jan 2023
How to run 2 power gui in a signal matlab file? I want to run 1 powergui with continuous signal and 1 power gui with phasor signal. What should I do plZ help
0 commentaires
Réponse acceptée
Joel Van Sickel
le 6 Mar 2020
Déplacé(e) : Sabin
le 4 Jan 2023
Hello Mitesh,
you can create a model reference and put one of your powergui blocks and the associated electrical network inside the model reference, and it will use the local model reference settings. This approach will require manually cleaning up the generated model reference and probably manually setting some of the output ports to work with complex signals (if you are using phasor).
You only need to put one of them in a model reference. It will be easier if you put the continuous time system in the model reference and leave the phasor system at the top level.
Regards,
Joel