Effacer les filtres
Effacer les filtres

MICROGRID BUILDING - sample time

5 vues (au cours des 30 derniers jours)
Antonio Bonì
Antonio Bonì le 20 Mai 2020
I'm working on electric microgrid building using simscape library. I have already put the PV, WF and the loads (both dynamic and static) models but there is some problems linked to sample time. The run time is very long time. What I should to do?
I have already tried to fix the fixed step size within solver selection and also changing the solver.
Can you give me some tips?

Réponses (1)

Sabin
Sabin le 4 Oct 2023
This depends on how the model looks like. If there are PWM controlled converters then the simulation will be relatively slow, depending on sampling rate can be painfully slow for longer simulation timespan. If the objective is to simulate at system level, the best way to speed up the simulation and to enable longer simulations is to use average converters and lower fidelity blocks.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by