Hi
I am currently playing with the following example and corresponding topic Active Noise Control with Simulink Real-Time provided by Mathworks
openExample('audio/ActiveNoiseControlWithSimulinkExample')
I need to use a speech signal as a source insted of a Noise as in example, in my case a speech signal is noise.
So I replace Noise source block to From Multimedia File block and specified a speech file.

Then when I run the model, I am getting the following error:
Simulation 1
05:43 PM Elapsed: 0.260 sec
MATLAB System block 'Test_FilteredX_LMS_ANC/LMS Update' error occurred when invoking 'validateInputsImpl' method of 'dsp.private.LMSUpdate'. The error was thrown from '
'C:\Program Files\MATLAB\R2020a\toolbox\dsp\dsp\+dsp\+private\LMSUpdate.m' at line 373'.
Caused by:
Expected Input to be a scalar.
Component:Simulink | Category:Block error
I tried to fix it by searching on the web, changing Audio output data type inside the From Multimedia File block, but dont really have an idea how to deal with it, since I had not really used Simulink before.
Thank you, I would appreciate your help
Have a nice day
0 commentaires
Réponse acceptée
jibrahim
le 12 Nov 2020
Hi Yurii,
I suspect the issue is that the LMS Update block requires scalar inputs, and the From Multimedia block output is a non-scalar frame. Open the dialog of the To Multimedia block, and set the 'Samples per audio channel' parameter to 1. Alternatively you can put an unbuffer block at the output of the to Multimedia block
Plus de réponses (0)