Unexpected noise in output voltage for buck converter

1 vue (au cours des 30 derniers jours)
Vasilica Cioban
Vasilica Cioban le 4 Juil 2021
Hello! I'm trying to simulate the buck converter using statespace equations. I don't understand why the output voltage has a ripple in the second photo (uncompensated system) and then, in the first one there is no ripple (compensated system)
  2 commentaires
madhan ravi
madhan ravi le 4 Juil 2021
Modifié(e) : madhan ravi le 4 Juil 2021
See the y axis scale of each picture.
Vasilica Cioban
Vasilica Cioban le 4 Juil 2021
Modifié(e) : Vasilica Cioban le 4 Juil 2021
no, this isnt the problem. i tried to zoom in the both of them and the first one is just a line without any ripple

Connectez-vous pour commenter.

Réponses (1)

Pat Gipper
Pat Gipper le 6 Juil 2021
The Puse Generator has a period of 1/100000 seconds, which is injecting 100 KHz pulses into your system. The ripple is simply the response to those pulse. Try setting Period=10 and Amplitude=24 and you will get rid of the ripple.

Produits


Version

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by