A répondu
Simulink to see Fourier
I put it in a Matlab Fcn block and it seems to work. See the attached file for details.

4 jours il y a | 0

A soumis


Frequency Response Analyzer
Perform frequency analysis of your Simulink model without linearization

4 mois il y a | 357 téléchargements |

Thumbnail

A répondu
PV MPPT Tracking Failing PV Array Current or Volatge Goes negative
Hi Ishaan. I found that a perturbation of 1% (Constant2 with value of 1) was too large in the controller. If you reduce the Cons...

presque 2 ans il y a | 0

| A accepté

A répondu
Model error in Simulink
It is having problems simulating an ideal op amp with infinite gain. If you intend on configuring the LM386 op amp as an invert...

environ 2 ans il y a | 0

A répondu
create a variable that changes its value(polynomial equation) for different time periods
Maybe something like this.

environ 2 ans il y a | 1

A répondu
Adding noise to a PID signal
Hi Nathan, You can use the lsim command to get a general response of your controller. I think you want to see the response when...

environ 2 ans il y a | 0

Question


Why the different response of two Simulink models?
Here is a follow-on question to this original question: How can I remove the few peaks before the overshoot, so I only have the...

environ 2 ans il y a | 1 réponse | 0

1

réponse

A répondu
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
Hi Samuel. I found tuning the derivative to be difficult too. Eventually I settled in on P=3.5, I=850, D=0.01 and N=850. The def...

environ 2 ans il y a | 0

| A accepté

A répondu
Can you let me know how to solve my errors? there are 4 errors in my simulink.
You had two issues. One was the integrators in Current_Controller were implimented using the Memory in the feedback path causing...

plus de 2 ans il y a | 1

| A accepté

A répondu
Data type mismatch error in Simulink
I saw a number of other issues in this model. 1) I think the inverter needs a ground reference added on the emitters of the low...

plus de 2 ans il y a | 0

| A accepté

A répondu
I need more explanations for the described hydraulic simulation
The pump in this model acts in a fixed displacement mode that produces a given flow rate regardless of its output pressure. When...

plus de 2 ans il y a | 0

A répondu
Filter background from audio file
Check out this previous answer. A different type of owl, but the same concept. Using Spectrogram to Design a Filter - (mathwork...

plus de 2 ans il y a | 0

A répondu
Simulation of the step response of a time delay system with a PID controller is contorted.
Those sharp transients in the closed loop response are the echoes of the step input as filtered by the transfer function that ar...

plus de 2 ans il y a | 0

A répondu
3rd Order ODE on Simulink
I approximated the required doublet input into an update to my comment with a summation of two very short pulse generators.

plus de 2 ans il y a | 0

A répondu
Why is my step response going down instead of up?
I would focus on your equation for zeta on line 60. It is resulting in a negative value (negative damping=bad!) which gives unst...

plus de 2 ans il y a | 1

| A accepté

A répondu
An electric circuit that includes a voltage source E with an internal resistance r, and a load resistance R is shown in the figure.
Probably late for your homework assignment. Can you write the equation for the power dissipated in R leaving R as a variable? Do...

plus de 2 ans il y a | 0

A répondu
Unexpected noise in output voltage for buck converter
The Puse Generator has a period of 1/100000 seconds, which is injecting 100 KHz pulses into your system. The ripple is simply th...

presque 3 ans il y a | 0

A répondu
Reproduce electric motor maps as images in Matlab Simulink
A similar question was answered suggesting importing the image into Matlab and then using ginput to extract coordinates of the a...

environ 3 ans il y a | 0

A répondu
Determining time elapsed in between two successive pulses of a signal
I updated your code a bit and fed in an artificial signal. It works but has a slight error due to loop delays running on my comp...

environ 3 ans il y a | 1

| A accepté

A répondu
How best to gather signals from all over a SIMULINK model to one subsystem
I moved your root model into a subsystem and used Bus Element Out(s), which was then connected to a new input on "get data" subs...

environ 3 ans il y a | 0

A répondu
A question about FOC current control for PMSM
The decoupling control is not quite correct for the PMSM motor you are using. You need to insert a multiplier by the number of p...

environ 3 ans il y a | 1

| A accepté

A répondu
How to measure the steady state amplitude of a control system output
Try using this app. It injects a sine wave and measures the gain and phase after a number of cycles that you specify. https://w...

environ 3 ans il y a | 0

A répondu
How to programmatically know if a block is a sink block?
I had to add some complexity to your code to make it work on my sample file. modelfile = 'SinkXY';% Or whatever your model file...

environ 3 ans il y a | 0

A répondu
Need help with simple Simulink
This seems to do the trick. It produces the following result.

environ 3 ans il y a | 1

| A accepté

A répondu
Simulation of a missile valve with Simscape
Hi Tom, A flip-flop will latch the valve shut once the flow reaches the threshold and keep it shut until you manually reset it....

environ 3 ans il y a | 1

| A accepté

A répondu
Coding philosophy : Is using global goto like using a global variable?
The thing about global visibility is that this signal can be accessible anywhere in the entire model, from sub-system to sub-sys...

environ 3 ans il y a | 1

A répondu
Calling a function using ode45 in App Designer results in unrecognized function
Note that I had answered my own question.

environ 3 ans il y a | 0

A répondu
How make single block diagram with this given parameters?
Hi. If you are using a Transfer Fcn block and have the coefficients defined in your workspace, then enter the equations in the b...

plus de 3 ans il y a | 1

| A accepté

A répondu
Frequency domain to Time domain Using IFFT : Symmetric figure problem
Your function produced a vector of complex numbers called "A". The original sequence will be reproduced using ifft(A). But the f...

plus de 3 ans il y a | 0