Feeds
Question
How to control intermediate variables when Simulink generates C code, and how to control the index values and function names for 2D lookup tables.
Hello, I encountered some problems when using Simulink to generate C code. My model is shown in Figure 1, and the model optimiza...
environ un mois il y a | 1 réponse | 0
1
réponseQuestion
I am currently working with Simulink and out of the sudden, I am unable to change the Model Configuration Parameters.
I am currently working with Simulink and out of the sudden, I am unable to change the Model Configuration Parameters. Whether I...
3 mois il y a | 1 réponse | 0
0
réponseQuestion
I want to customize a 34cc vapor injection compressor model in Simscape. How do I go about it? How can I simulate the vapor injection process and the intermediate compression
Hello,I want to customize a 34cc vapor injection compressor model in Simscape to simulate and compare the performance of a vapor...
10 mois il y a | 1 réponse | 0
0
réponseQuestion
Two-phase flow control valve
Hello, is there a two-phase flow regulator in Simscape that does not change the pressure on both sides?
plus d'un an il y a | 1 réponse | 0
1
réponseQuestion
The particle swarm optimization algorithm optimizes the scale factor and quantization factor of the fuzzy PID controller
I want to use the particle swarm optimization algorithm to optimize the scale factor and quantization factor of the fuzzy PID co...
plus d'un an il y a | 1 réponse | 0
1
réponseQuestion
The element 1 in SCDPotentialLinearizationIOs structure is not referring to an existing block in the model。
Hello,I don't know where to operate when adjusting the PI control of the model, and suddenly the following error appears: The el...
plus d'un an il y a | 1 réponse | 0
1
réponseFuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello,I don't seem to have tried the peak you mentioned, I'm not sure what conditions are suitable for him, I adjusted his param...
plus d'un an il y a | 0
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I don't have his differential equations here, I'm using the compressor components in Simscape and using Simluink to control the ...
plus d'un an il y a | 0
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I haven't tried this before, I'm a direct control of the actuator, but I feel that this phenomenon seems a little strange. It's ...
plus d'un an il y a | 0
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello, I found that the model you built does not seem to initialize the PID parameters, and directly input the output of the fuz...
plus d'un an il y a | 0
Question
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
In 'EV_Thermal_Management_wendukongzhi_zhileng/Controls/Compressor Control/ÿÿÿÿ/Fuzzy Logic Controller', input 2 expects a val...
plus d'un an il y a | 2 réponses | 0
2
réponsesQuestion
I want to use a solenoid valve to achieve two-phase flow on/off
Hello,I want to use a solenoid valve to achieve two-phase flow on/off, I tried to use the Orifice (2P) module, but its cross-flo...
environ 2 ans il y a | 1 réponse | 0
1
réponseDiscussion
Two-phase flow solenoid valve
Hello, I want to use a solenoid valve to open and close the two-phase flow circuit, and I should use those elements to achieve i...
environ 2 ans il y a | 0
Question
2P-2P Heat Exchanger
I am trying to build a two-phase flow heat exchanger (2P-2P), which means that the heat exchanger on both sides of the heat exch...
plus de 2 ans il y a | 1 réponse | 0
1
réponseQuestion
two-phase flow 4-way valve
I want to build a two-phase flow 4-way valve using Simscape, what do I do?
plus de 2 ans il y a | 1 réponse | 0
1
réponseQuestion
Why is my electronic expansion valve not working
Hello, I am building a model of a heat pump air conditionerI am trying to use an electronic expansion valve for throttling, but ...
plus de 2 ans il y a | 1 réponse | 0
0
réponseQuestion
Simscape how to set up a multi-process evaporator or condenser
Hello, I want to create a parallel flow microchannel condenser with four processes but there doesn't seem to be a similar module...
plus de 2 ans il y a | 1 réponse | 0
1
réponseQuestion
Custom quasi-secondary compressor models report errors
I want to add a make-up port to the controllable mass flow element, but when I run it he gets the error: Cannot find parameter '...
plus de 2 ans il y a | 1 réponse | 0
1
réponseQuestion
Heat Pump Air Conditioner
I'm trying to build a make-up enthalpy heat pump air conditioner with Simscape but I don't know how to start, does anyone know h...
plus de 2 ans il y a | 1 réponse | 0