Statistiques
RANG
4 336
of 301 637
RÉPUTATION
12
CONTRIBUTIONS
0 Questions
24 Réponses
ACCEPTATION DE VOS RÉPONSES
0.00%
VOTES REÇUS
2
RANG
5 877 of 21 366
RÉPUTATION
209
CLASSEMENT MOYEN
3.00
CONTRIBUTIONS
22 Fichiers
TÉLÉCHARGEMENTS
287
ALL TIME TÉLÉCHARGEMENTS
2092
RANG
of 175 891
CONTRIBUTIONS
0 Problèmes
0 Solutions
SCORE
0
NOMBRE DE BADGES
0
CONTRIBUTIONS
0 Publications
CONTRIBUTIONS
0 Public Chaîne
CLASSEMENT MOYEN
CONTRIBUTIONS
0 Point fort
NOMBRE MOYEN DE LIKES
Feeds
Why does the battery SoC saturate in my CubeSat EPS Simulink model with simplified solar and load modelling?
your SoC saturates because the model creates a non physical feedback loop and lacks battery constraints causing artificial energ...
15 jours il y a | 0
A soumis
Modeling and Simulation of an AC-DC Boost Converter
The system works by first converting AC to DC using a diode bridge, then boosting and regulating the DC voltage using a boost co...
15 jours il y a | 9 téléchargements |
I have a simulation of a PMSM controlled by FOC using the SVPWM technique, and I would like to convert it to FOC using hysteresis current control.mention if there are errors.
Hysteresis Band Current Controller - File Exchange - MATLAB Central.-check it for reference Replace the inner current-contro...
environ 2 mois il y a | 0
How do I get the total impedance for one circuit of impedances?
Use only Specialized Power Systems (SPS) blocks and avoid Simscape impedance blocks entirely. Insert a Voltage Measurement block...
environ 2 mois il y a | 0
A soumis
Two-Switch Forward Converter
Isolated DC-DC conversion using high-frequency transformer - Two-switch topology with automatic core reset - Reduced voltage str...
environ 2 mois il y a | 7 téléchargements |
A soumis
Solar Fed Dual Active Bridge Converter with MPPT
Simulink model of solar PV fed DAB converter with MPPT, phase shift control, efficiency and power transfer analysis.
3 mois il y a | 22 téléchargements |
Disturbance observer and prescribed time controller
Prescribed-time terms 1/(Tfc−t)1/(T_{fc}-t)1/(Tfc−t) blow up near TfcT_{fc}Tfc in discrete simulation, creating an impulsive c...
3 mois il y a | 0
A soumis
AI-Based Dual Active Bridge DC Nanogrid System
Solar–Fuel Cell DC nanogrid with ANN-based DAB phase control and adaptive RL energy management for cost and CO₂ reduction.
3 mois il y a | 7 téléchargements |
Comment utiliser les transformées de Laplace ? How to use Laplace transforms
Solving differential equations using the Laplace transform in MATLAB involves converting a time-domain differential equation int...
4 mois il y a | 0
A soumis
three-level NPC–DAB–CLLC converter
three-level NPC–DAB–CLLC converter
4 mois il y a | 35 téléchargements |
A soumis
Dual Active Bridge (DAB) DC–DC converter with pi controller
A Dual Active Bridge (DAB) DC–DC converter is most commonly controlled using phase-shift modulation, where the phase difference ...
5 mois il y a | 56 téléchargements |
A soumis
DCDCBUCKBOOSTCONVERTER
buck–boost converter is a DC–DC converter in which the input is a stiff voltage source and the output voltage can be either lowe...
5 mois il y a | 1 téléchargement |
Can you use MATLAB with AutoCad?
Yes—AutoCAD and MATLAB are used together in architectural acoustics. AutoCAD → draws the room geometry and layout MATLAB → cal...
5 mois il y a | 0
| A accepté
A soumis
Realistic dishwasher controller simulation
Realistic dishwasher controller simulation comparing PI, Fuzzy, Reinforcement Learning, and ANN methods with 230V/500W load mode...
5 mois il y a | 1 téléchargement |
A soumis
Nanogrid with solar cell
A nanogrid is a small-scale power system (typically < 10 kW) supplying local DC and/or AC loads using distributed energy sources...
5 mois il y a | 2 téléchargements |
Can't plot function
x = linspace(0,10); y = sqrt(1+x.^2)./sqrt(x.^4-x.^2+1); plot(x,y);
5 mois il y a | 0
A soumis
Fast Averaged Model Simulation of Dual Active Bridge (DAB)
Averaged DAB model for real-time-like speed,Comparative analysis of PI, FLC, ANN, and AI-inspired controllers
6 mois il y a | 13 téléchargements |
How to change font size of legend in simulink
You can change the font size of labels in a Simulink Scope either through the graphical interface or using MATLAB commands. To d...
7 mois il y a | 0
How to enable the Legend of the Simulink Scope??
Open the Scope, then run:fig = get_param(gcb,'ScopeFigureHandle'); % get scope’s figure handle print(fig,'-depsc','scope_output...
8 mois il y a | 0
Power Systems Simulation Onramp Bug, three phase systems, three phase domain, 2/3 blocks Task 4 Does the following block have the correct parameter settings?
ONCE THE CHECK THE RLC BRANCH AND CHECK IT WHETHER IT WAS KEPT AS EXPANDED THREE PHASE PORTS , OR ELSE REMOVE THE RLC , IN LIBRA...
8 mois il y a | 0
Power Systems Simulation Onramp error
@Taimour THE MISTAKE YOU HAVE DONE IS THAT YOU CONNECTED THREE PHASE GROUNDED NEUTRAL IN THE SCREENSHOT THAT IS THE MISTAKE . RE...
8 mois il y a | 0
Jag vill förlänga min licens
To renew your MATLAB license before September 30, log in to the MathWorks License Center, renew your license, and then reactivat...
8 mois il y a | 0
A soumis
single-phase power-factor corrected AC-DC halfbridge boost
The design focuses on a single-phase power-factor-corrected (PFC) half-bridge boost converter operating in Discontinuous Conduct...
8 mois il y a | 10 téléchargements |
Help needed with simulink onramp Discrete systems
IN SCOPE you have settings , click on display and you have to enable the legend in the scope . then it will be activated and th...
8 mois il y a | 1
Error in Load Flow analyzer with Phase shifted Transformer
Use the transformer’s winding connection + clock position (e.g. Yd5/Dy5 for ±150°) instead of manually cross-connecting delta te...
9 mois il y a | 0
When I choose to simulate temperature effects of battery, it takes too much time to simulate
Simulating battery temperature effects in MATLAB R2019b can be slow because it adds thermal-electrical coupling, making the syst...
9 mois il y a | 0
how do i share matlab with my student team?
MATLAB code can be shared easily through GitHub. If it’s Simulink, then all team members need MATLAB/Simulink installed (same or...
9 mois il y a | 0




