photo

Girisha Joshi


St. Joseph engineering Cllege

Last seen: plus de 3 ans il y a Actif depuis 2012

Followers: 0   Following: 0

Message

Designation: Lecturer
working on electrical machine simulation using simulink
Professional Interests: Electrical machines and control systems

Statistiques

Feeds

Afficher par

Question


Synchronising plant and controller
I am using a controller in my simulink model. how to make sure that controller works only after previous controller output (n-1)...

plus de 5 ans il y a | 1 réponse | 0

1

réponse

Question


ABC to dq0 conversion in simulink
Hi.... I am Girisha Joshi a research scholor from NMAMIT, Nitte, Karnataka, India. I am developing a vector control model of 3 p...

plus de 6 ans il y a | 1 réponse | 0

0

réponse

Question


AC voltage source is not giving sinusoidal output in matlab version 2010B
I have rigged up a simple circuit consisting of ac voltage source and a resistor. For run time 20ms i am getting pure sine wave....

plus de 10 ans il y a | 1 réponse | 0

0

réponse

Question


distortions in power supply
i have developed a 3 phase power supply using cos function using simulink . Its gives distortions when i increase the run time t...

plus de 11 ans il y a | 1 réponse | 0

0

réponse

Question


why signal generator is not giving proper sawtooth wave for frequency of 1khz and run time of 100 seconds
why signal generator is not giving proper sawtooth wave for frequency of 1khz and run time of 100 seconds

environ 12 ans il y a | 1 réponse | 0

1

réponse

Question


how to use dot convention of transformer in simulink
how to use dot convention of transformer in simulink

environ 12 ans il y a | 1 réponse | 0

1

réponse

Question


10kW permanent magnet synchronous machine data.....
I am developing wind energy conversion system. I am using PMSM in built model. I need corresponding values of Ld, Lq, flux link...

plus de 12 ans il y a | 1 réponse | 0

1

réponse

Réponse apportée
how to get RMalS,peak values for control algorithm from model.
Thank u so much...I used 'continuous RMS' block which gave me the RMS value,from which maximum value can also be obtained by mul...

plus de 12 ans il y a | 0

Question


how to get RMalS,peak values for control algorithm from model.
I am developing wind energy conversion system.I am using hill climb searching algorithm for which i want to sample the inverter ...

plus de 12 ans il y a | 2 réponses | 0

2

réponses

Question


simscape and simpower sysystem
I want to connect inverter output to variable resistor.Two blocks are in simpowersystem and simscape respectivy. how to connect?...

plus de 12 ans il y a | 3 réponses | 0

3

réponses

Question


using .m file in simulink model
In my project, I am using simulink to model the system.Whose intermediate data has to be used in certain .m file and its output ...

presque 13 ans il y a | 1 réponse | 0

1

réponse

Question


data transfer b/n .m file to .mdl simulink model.
I am developing a wind energy conversion system. i would like to control the inverter current for which hill climb searching alg...

presque 13 ans il y a | 1 réponse | 0

0

réponse